Fix the Annoying Event ID 5785


I found this in a blog a while ago but can’t find it now so here it is…
If you see this error in your event log the fix is fairly simple.

Event Type: Error
Event Source: Office SharePoint Server
Event Category: Publishing Cache
Event ID: 5785
Date:  5/19/2008
Time:  6:19:13 AM
User:  N/A
Computer: <server>
Description:
Unable to connect publishing custom string handler for output caching.  IIS Instance Id is ‘461376054’, Url is ‘http://blahblah/page.aspx&#8217;.

The solution is to modify the web.config of the application. Remove the PublishingHttpModule module that was added by the root web.config:

<httpModules>

   <remove name=”PublishingHttpModule” />

</httpModules>

 

 

6 Responses to “Fix the Annoying Event ID 5785”

  1. Yuko Says:

    Hello, I have found this error in my MOSS2007 server too. I could not public document about this in the MS pages. Is it a bug??

  2. Kerry Says:

    I don’t think it’s technically a “bug”. Just an annoying Event message… 🙂

  3. carol Says:

    Hi,
    I’m suffering the same 5785 errors, and I’ve tried to add and other solutions mentioned in other blogs as add , but anything works.